fieldcommunicator

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isola

description:Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated Barrier ...
BASIC INFO

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

 

 

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

 

·  2-channel isolated barrier

·  24 V DC supply (Power Rail)

·  Dry contact or NAMUR inputs

·  Relay contact output

·  Line fault detection (LFD)

·  Reversible mode of operation

·  Up to SIL 2 acc. to IEC 61508

 

 

 

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

 

The KFD2-SR2-EX2.W is a 2-channel isolated Switch Amplifier for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area. The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switches S1 and S2. Switch S3 is used to enable or disable line fault detection of the field circuit. During an error condition, the relays revert to their de-energized state and the LEDs indicate the fault according to NAMUR NE44. An unique collective error messaging feature is available when used with the power rail system.

 

·  24VDC Supply voltage

·  Dry contact or NAMUR inputs

·  Relay contact output

·  Line fault detection (LFD)

·  Reversible mode of operation

·  Up to SIL2 according to IEC 61508

 

Specification of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

General specifications of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 
Signal type Digital Input
Functional safety  related parameters
Safety Integrity Level (SIL) SIL 2
Supply of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 
Connection Power Rail or terminals 14+, 15-
Rated voltage 20 ... 30 V DC
Ripple ≤ 10 %
Rated current ≤ 50 mA
Power dissipation 1 W
Power consumption < 1.3 W
Input of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 
Connection side field side
Connection terminals 1+, 2+, 3-; 4+, 5+, 6-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratio min. 20 ms / min. 20 ms
Output of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 
Connection side control side
Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Output I, II signal, relay
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Minimum switch current 2 mA / 24 V DC
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Mechanical life 107 switching cycles

 

Function of Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

 

This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.

 

The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switches S1 and S2. Switch S3 is used to enable or disable line fault detection of the field circuit.

 

During an error condition, the relays revert to their deenergized state and the LEDs indicate the fault according to NAMUR NE44.

 

A unique collective error messaging feature is available when used with the Power Rail system.

 

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 

 

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W

KCD2-SR-Ex1.LB
KCD2-SR-Ex2
KFA6-DU-Ex1.D
KFA6-ER-Ex1.W.LB
KFA6-SOT2-Ex2
KFA6-SR2-Ex1.W
KFA6-SR2-Ex1.W.LB
KFA6-SR2-Ex2.W
KFA6-SR2-Ex2.W.IR
KFD2-DU-Ex1.D
 
KFD2-ELD-Ex16
KFD2-ER-Ex1.W.LB
KFD2-SH-Ex1
KFD2-SH-Ex1.T.OP
KFD2-SOT3-Ex1.LB
KFD2-SOT3-Ex1.LB.IO
KFD2-SOT3-Ex2
KFD2-SOT3-Ex2.IO
KFD2-SR2-Ex1.W
KFD2-SR2-Ex1.W.LB
 
KFD2-SR2-Ex2.W
KFD2-SR3-Ex2.2S
KFD2-SRA-Ex4
KFD2-ST3-Ex1.LB
KFD2-ST3-Ex2
KHA6-SH-Ex1
KCD2-SON-Ex1
KCD2-SOT-Ex1.LB
KCD2-SOT-Ex2
KCD2-SOT-Ex2.SP
 

Pepperl+Fuchs Switch Amplifier KFD2-SR2-Ex2.W K System Isolated  Barrier 


KCD2-SR-Ex1.LB.SP
KCD2-SR-Ex2.SP
KCD2-ST-Ex1.LB
KCD2-ST-Ex2
KFA5-SOT2-Ex2
KFA5-SR2-Ex1.W
KFA5-SR2-Ex1.W.LB
KFA5-SR2-Ex2.W
KFA5-SR2-Ex2.W.IR
KFD2-SH-Ex1.T
 
KFD2-SOT3-Ex2.IO-Y1
KCD2-SON-Ex1.R1
KCD2-SON-Ex1.SP
KCD2-SON-Ex2
KCD2-SON-Ex2.R1
KCD2-SON-Ex2.SP
KCD2-SOT-Ex1.LB.SP
KCD2-ST-Ex1.LB.SP
KCD2-ST-Ex2.SP
KFA4-SR2-Ex2.W
 
KFA5-DU-Ex1.D
KFA4-SR2-Ex1.W
KFA4-SR2-Ex1.W.LB
KFD2-SOT2-Ex1.LB
KFD2-SOT2-Ex1.LB.IO
KFD2-SOT2-Ex2
KFD2-SOT2-Ex2.IO
KFD2-SOT2-Ex2.IO-Y181008
KFD2-SR2-Ex2.2S
KFD2-ST2-Ex1.LB
KFD2-ST2-Ex2

 



We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply Yokogawa ,Honeywell,Siemens,ABB,FLUKE,Endress+Hauser,Schneider Electric,Moeller,FUJI,Omron,Pepperl+Fuchs,Hima,Yaskawa, Norgren, Hach, Weidmuller ,Phoenix,MTL,Testo etc.
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat) 

Previous: Next:Pepperl Fuchs Switch Amplifier KFD2-SH-Ex1.T K System Isola
 Footer begin -->