BASIC INFO
Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
Features of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
• Interface for Power Rail
• Supply current ≤ 4 A
• Replaceable fuse
• Relay contact output, reversible
• LED status indication
Datasheet excerpt: Technical data of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
Product Description of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
---|---|---|
Power Feed Module |
Supply of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
---|---|---|
Connection |
terminals 11+, 12- terminals 8+, 9- |
|
Rated voltage |
20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. |
|
Fusing |
5 A recommended maximum utilization of the fuse: 80 % |
|
Power dissipation | ≤ 1 W | |
Output of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Connection | Power Rail | |
Output rated operating current | max. 4 A | |
Fault signal | relay output: NO contact | |
Contact loading | 30 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Indicators/settings of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 100 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier | ||
Certificate | TÜV 00 ATEX 1618 X | |
Marking | II 3G Ex nA nC IIC T4 | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
Detailed Models of Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
KFD2-SR2-Ex2.W
KFD2-SL2-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1
KFD2-SR2-EX.1.W.LB
KFD2-EB2.R4A.B
KFD2-SCD2-EX1.LK
KFD2-SR2-EX2.W
KFD2-SL2-EX2.B
KFD0-TT-EX1
KFD0-TR-EX1
KFD2-STC4-EX2
KFD2-UFC-EX1.D
KFD2-SCD2-EX2-LK
KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O
KFD2-SH-EX1.T.OP
KFD2-SR2-EX2.2S
KFD2-BR-1.PA.93
KFD2-UT2-EX2
KFD2-UFC-EX1.D
KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB
KFD2-STC4-EX1.20
KFD2-STC4-1.20
KFD2-SCD2-EX2.LK
KFD2-SCD2-2.LK
KFD2-SH-EX1
KFD0-SD2-Ex2.1245
KFD2-SL2-Ex1.LK
KFD2-BR-Ex1.3PA.93
KFD2-CD2-EX2
KFD2-UT2-EX2
KFD2-STC4-EX1.2O
KFD2-CR4-1.2O
KFD2-CD2-EX1
KFD2-SL2-EX2
KLD2-PR-1.IEC
KFD2-WAC2-EX1.D
KFD2-UFT-EX2.D
KFD2-UFC-1.D
KFD-STC4-EX1.2O.DE
KFD2-SCD2-EX1
KFD2-PT2-Ex1
KFD2-SR2-EX2.2S
KFD0-SD2-EX1.1045
KCD2-E2L
KCD2-STC-EX1
KFD2-SR2-EX1.W
KFD2-SCD2-EX1-LK
KCD2-SCD-EX1
KFD2-UT2-EX1
KFD2-VR4-EX1.26
KFD2-SR2-EX1.W.LB
KFDO-RSH-1
KFD2-GS-1.2W
KFD2-EB.R4A.B
KFD0-SCS-EX1.55
KFD2-EX1.32
KFD2-STC4-Ex1-Y1.
KFD2-SR2-EX2.2S
KFD2-SCD2-EX2.LK
KFA5-SR2-EX1.W.LB
KFD2-RR-EX1
KFD2-SCD-EX1.LK
KFA6-STR-1.24.500
Z787.H
Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
KFD0-CS-EX2.50P
KFD0-CS-EX2.51P
KFA6-SR2-EX1.W.LB
KFA5-SR2-EX1.W
KFD2-ST2-EX2
KFD2-DWB-1.D
KFD2-UT-EX1
KFD2-SR2-2.2S
HD2-FBPS-1.500
HD2-DM-B
KFD2-GU-Ex1.D
KFD2-PT2-EX1-5
KFD2-DWB-Ex1.D
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFU8-DW-1.D
KFD0-RO-Ex2
S1SD-1TI-1U
KFD2-GUT-1.D
KFD0-SCS-1.55
KFD2-DWB-Ex1.D
KFD2-PT2-EX1-5
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFD0-RO-Ex2
KFD2-GUT-1.D
KFD2-SCD2-1.LK
KFD2-GU-Ex1
Pepperl Fuchs KFD2-EB2 Power Feed Module KFD2-EB2 Safety Barrier
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
We mainly supply Yokogawa ,Honeywell,Siemens,ABB,FLUKE,Endress+Hauser,Schneider Electric,Moeller,FUJI,Omron,Pepperl+Fuchs,Hima,Yaskawa, Norgren, Hach, Weidmuller ,Phoenix,MTL,Testo etc.
Why choose us?
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
Packaging:
Imported with original packaging or standard export packing.Customize design is acceptable.
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)